HSWPE 1
The amounts of water flowing from a certain
catchment area at the proposed dam site are tabulated as follows. Determine: - The minimum
capacity of the reservoir if the water is to be used to feed the turbines of the hydropower plant at a uniform rate and no water is to be spilled over.
- The initial
storage required to maintain the uniform demand as above.
|
Month
|
Jan
|
Feb
|
Mar
|
Apr
|
May
|
Jun
|
Jul
|
Aug
|
Sep
|
Oct
|
Nov
|
Dec
|
|
Inflow
x105m3
|
2.83
|
4.25
|
5.66
|
18.4
|
22.64
|
22.64
|
19.81
|
8.49
|
7.10
|
7.10
|
5.65
|
5.66
|
ANS:
The
computation is done in a tabular form below
This value has been entered in column (3) of the below table.
|
Month
|
Inflow
(x105m3)
|
Av.
Demand
(x105m3)
|
Deficit
(x105m3)
|
Surplus
(x105m3)
|
|
1
|
2
|
3
|
4
= 3 - 2
|
5
= 2 - 3
|
|
January
|
2.83
|
10.8533
|
8.0233
|
|
|
February
|
4.25
|
10.8533
|
6.6033
|
|
|
March
|
5.66
|
10.8533
|
5.1933
|
|
|
April
|
18.40
|
10.8533
|
|
7.5467
|
|
May
|
22.64
|
10.8533
|
|
11.7867
|
|
June
|
22.64
|
10.8533
|
|
11.7867
|
|
July
|
19.81
|
10.8533
|
|
8.9567
|
|
August
|
8.49
|
10.8533
|
2.3633
|
|
|
September
|
7.10
|
10.8533
|
3.7533
|
|
|
October
|
7.10
|
10.8533
|
3.7533
|
|
|
November
|
5.66
|
10.8533
|
5.1933
|
|
|
December
|
5.66
|
10.8533
|
5.1933
|
|
|
Sum
|
130.24x105
|
130.24x105
|
|
40.0766x105
|
Since
no water is to be spilled, the minimum capacity will be equal to the sum of the
surplus water.